Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://hdl.handle.net/20.500.12701/1738
Название: Rough Titanium Oxide Coating Prepared by Micro-Arc Oxidation Causes Down-Regulation of hTERT Expression, Molecular Presentation, and Cytokine Secretion in Tumor Jurkat T Cells
Авторы: Khlusov, Igor
Litvinova, Larisa
Shupletsova, Valeria
Khaziakhmatova, Olga
Melashchenko, Elena
Yurova, Kristina
Leitsin, Vladimir
Khlusova, Marina
Pichugin, Vladimir
Sharkeev, Yurii
Ключевые слова: titanium substrate
surface electrostatic potential
TiO2 nanoparticles
tumor cell death
reactive oxygen species
in vitro
Дата публикации: 28-фев-2018
Издательство: MDPI
Серия/номер: Materials;Volume 11, Issue 3
Краткий осмотр (реферат): The response of the human Jurkat T cell leukemia-derived cell line (Jurkat T cells) after 24 h of in vitro exposure to a titanium substrate (12 × 12 × 1 mm3) with a bilateral rough (Ra = 2.2–3.7 μm) titanium oxide coating (rTOC) applied using the micro-arc method in a 20% orthophosphoric acid solution was studied. A 1.5-fold down-regulation of hTERT mRNA expression and decreases in CD3, CD4, CD8, and CD95 presentation and IL-4 and TNFα secretion were observed. Jurkat T cell inactivation was not correlated with the generation of intracellular reactive oxygen species (ROS) and was not mediated by TiO2 nanoparticles with a diameter of 14 ± 8 nm at doses of 1 mg/L or 10 mg/L. The inhibitory effect of the rTOC (Ra = 2.2–3.7 μm) on the survival of Jurkat T cells (Spearman’s coefficient rs = −0.95; n = 9; p < 0.0001) was demonstrated by an increase in the necrotic cell count among the cell population. In turn, an elevation of the Ra index of the rTOC was accompanied by a linear increase (r = 0.6; p < 0.000001, n = 60) in the magnitude of the negative electrostatic potential of the titanium oxide surface. Thus, the roughness of the rTOC induces an electrostatic potential and decreases the viability of the immortalized Jurkat T cells through mechanisms unrelated to ROS generation. This may be useful for replacement surgery applications of rough TiO2 implants in cancer patients.
URI (Унифицированный идентификатор ресурса): https://doi.org/10.3390/ma11030360
http://hdl.handle.net/20.500.12701/1738
Располагается в коллекциях:Materials

Файлы этого ресурса:
Файл Описание РазмерФормат 
10.3390_ma11030360.pdf.pdf2,22 MBAdobe PDFПросмотреть/Открыть